Compare with a laser measurement

How closely does a thermal vibration model match a measured membrane?

Measurement guide

Read the measured panels

Barg and colleagues scanned a 1 mm square silicon nitride membrane with a focused laser interferometer. With the shaker off, they filtered each displacement trace around a resonance and reported its root mean square (RMS) in picometres. RMS describes the size of the thermal motion at each spot.

Figure 3, left column. Find a at 410 kHz, d at 821 kHz and e at 1,232 kHz. The right column in the article contains the authors’ calculated maps. All three crops share the colour bar shown here. One picometre is 10−12 metres.

Shared measured-panel colour scale, from near-white at zero to dark purple above the 4 picometre tick.

How far apart are the maps?

Across 484 positions per mode, the model’s no-fit relative spatial L² errors range from 41.2% to 50.4%. The bars show the lab’s calculation from the published figure. A shorter bar means a smaller mismatch across the grid.

Mode (1, 1)

Figure 3a

410 kHz measured · Used to fit the scale

Panel a. One broad area of higher RMS displacement around the centre.
Measured RMS displacement
No fit
46.6%
One fitted scale
26.3%

The scale is chosen using this panel, so the smaller error is an in-sample result.

Read values in picometres
Largest RMS read from the measured raster
4.459 pm
No-fit model RMS at a lobe peak
4.300 pm
No-fit residual RMSE
0.742 pm
Scaled residual RMSE
0.419 pm

Mode (2, 2)

Figure 3d

821 kHz measured · Held out of the fit

Panel d. Four areas of higher RMS displacement, one in each quadrant.
Measured RMS displacement
No fit
41.2%
One fitted scale
40.6%

The same scale reduces the error slightly on this panel.

Read values in picometres
Largest RMS read from the measured raster
2.781 pm
No-fit model RMS at a lobe peak
2.148 pm
No-fit residual RMSE
0.407 pm
Scaled residual RMSE
0.401 pm

Mode (3, 3)

Figure 3e

1,232 kHz measured · Held out of the fit

Panel e. Relatively faint, uneven RMS displacement, with multiple local peaks.
Measured RMS displacement
No fit
50.4%
One fitted scale
57.0%

The same scale increases the error on this panel.

Read values in picometres
Largest RMS read from the measured raster
2.389 pm
No-fit model RMS at a lobe peak
1.431 pm
No-fit residual RMSE
0.432 pm
Scaled residual RMSE
0.488 pm

The raster maximum is the largest sampled value. The model’s lobe peak is a continuous maximum. The bar chart compares the maps at matched grid positions.

Fitting one multiplier to panel a does little for d and worsens e. This comparison does not establish absolute amplitude accuracy.

How the comparison was made

A model with a physical amplitude

The model uses an ideal square membrane with zero displacement on its edges. The shape φ = sin(mπx/L) sin(nπy/L) has peak magnitude one. Its modal mass in that normalization is M = ρhL²/4 = 33.75 ng, using Barg et al.’s nominal side L = 1 mm, thickness h = 50 nm and density ρ = 2,700 kg/m³.

In this model m and n count antinodes along the two sides, so the wave numbers are mπ/L and nπ/L. Equation (5) in the article prints wave numbers with an extra factor of two for indices described as antinode counts. The lab uses the fixed-edge formula above and the authors’ mode labels in Figure 3.

Thermal equipartition gives RMS displacement |φ|√[kBT/(M(2πf)²)], with Boltzmann constant kB, T = 300 K as a modelling assumption and the reported frequency f for each mode as an input. The prediction treats the laser spot as a point and is already in RMS units.

No fit, one fitted scale and the error metric

The no-fit baseline uses the formula as written on a 22 × 22 grid of cell centres. No panel gets its own amplitude normalization. The comparison with one fitted scale multiplies all three model maps by 0.715029, a least-squares factor from panel a alone. The recorded displacement values for d and e were held out of this fit.

Relative spatial L² error is √[Σ(model − reading)² / Σ(reading²)] over one map, displayed as a percentage. Residual RMSE is √[Σ(model − reading)² / 484] in pm. The relative error compares both scale and spatial pattern.

Reading precision and measurement limitations

The lab reconstructed the 22 × 22 values from each measured panel using its image colours and Figure 3’s printed colour bar. The frozen extraction uses the median of nine nearby colour lookups for each value and compatible colour-bar positions to bound the image reading. The calibrated bar reaches about 4.503 pm, above the final printed tick at 4 pm. The nominal comparison uses the frozen RGB distance tolerance of 12. Repeating the interval construction at 8 or 20 changes the reading intervals while leaving the nominal values fixed.

For example, cell row 11, column 9 of panel a (zero-based, rows from the top) reads about 4.459 pm with an image-reading interval of about 3.821–4.503 pm at tolerance 12. The upper bound in this example reaches the top of the colour lookup table. The interval describes digitization alone. The located sources do not supply the raw traces or numeric grid, precise grid registration, effective filter response or a full experimental uncertainty budget. Those limits prevent interpreting these errors as a metrological accuracy estimate.

Source

Andreas Barg, Yeghishe Tsaturyan, Erik Belhage, William H. P. Nielsen, Christoffer B. Møller and Albert Schliesser, Measuring and imaging nanomechanical motion with laser light, Applied Physics B 123, 8 (2017), §3.1 and Figure 3. DOI 10.1007/s00340-016-6585-7

Figure 3 crops by Barg et al., CC BY 4.0 per the publisher’s current article. Panels a, d and e and the measured colour bar were cropped from the current publisher image, converted to PNG and resized for display. The lab’s numerical comparison uses a separately archived higher-resolution rendition of Figure 3.